Physics & Measurement Notes

Units & Dimensions · Dimensional Analysis · Significant Figures · Error Analysis · Measuring Instruments

SI UnitsDimensional AnalysisSignificant Figures Error AnalysisVernier CalliperScrew Gauge Dimensional FormulaePrinciple of Homogeneity
Advertisement
1

Physical Quantities & SI Units

Types of Physical Quantities
S.No.Fundamental QuantitySI UnitSymbol
1LengthMetrem
2MassKilogramkg
3TimeSeconds
4TemperatureKelvinK
5Amount of SubstanceMolemol
6Electric CurrentAmpereA
7Luminous IntensityCandelacd
Special Units of Length

Unit Conversion — Key Formula

Since numerical value × unit = constant:

\[ n_1 u_1 = n_2 u_2 \]

where n = numerical value, u = unit. If unit increases → numerical value decreases.

\[ n_2 = n_1 \left[\frac{M_1}{M_2}\right]^a \left[\frac{L_1}{L_2}\right]^b \left[\frac{T_1}{T_2}\right]^c \]

where a, b, c are powers of M, L, T in the dimensional formula.

2

Dimensional Analysis & Principle of Homogeneity

Principle of Homogeneity
e.g. v = at + b  →  [v] = [at]  →  [b] = LT−1, [a] = LT−2
Both terms on RHS must have same dimension as LHS (velocity = LT⁻¹)

Applications of Dimensional Analysis

⚡ Trick — Deriving Time in New Unit System

Given: new unit of length = 2 m, new unit of acceleration = 8 m/s²

\[ [T] = [L]^{1/2}[a]^{-1/2} \quad \Rightarrow \quad T_{new} = \sqrt{\frac{L_{new}}{a_{new}}} = \sqrt{\frac{2}{8}} = \frac{1}{2} \text{ s} \]
Worked Examples
Q: In P = P₀e−at², find dimension of a.
Exponent must be dimensionless → [at²] = 1 → [a][T²] = 1 → [a] = T−2
Ans: [a] = T−2 ✓
Q: In y = A sin(ωt − kx), find dimensions of ω and k.
Angle must be dimensionless → [ωt] = 1 → [ω] = T−1  |  [kx] = 1 → [k] = L−1
Ans: [ω] = T−1, [k] = L−1 ✓
Q: v = at + b/(t+c). Find dimension of b.
[v] = LT−1; [b/(t+c)] = LT−1 → [b] = LT−1 × T = L (since [t+c] = T)
Ans: [b] = L ✓
Advertisement
3

Limitations of Dimensional Analysis

Cannot Do the Following
4

Important Dimensional Formulae

Basic Quantities
Physical QuantityDim. FormulaSame Formula Quantities
Work / Energy / Torque[ML²T−2]Work, KE, PE, Heat, Torque
Power[ML²T−3]Power, VI, I²R, V²/R
Force / Weight[MLT−2]Force, weight, tension, thrust, friction
Momentum / Impulse[MLT−1]Linear momentum, impulse
Angular Momentum / Planck's h[ML²T−1]L = Iω, h = E/f
Time[T]Time period, RC, √LC, L/R
Angular velocity / Frequency[T−1]ω, f, velocity gradient, decay constant
Extended Formulae — Derivation Table
Physical QuantityDerivationDim. Formula
Gravitational Constant GF = Gm₁m₂/r² → G = Fr²/m²[M−1L³T−2]
Planck's Constant hE = hf → h = E/f[ML²T−1]
Boltzmann Constant kBE = kBT → kB = E/T[ML²T−2K−1]
Capacitance CE = ½CV² → C = 2E/V²[M−1L−2T⁴A²]
Electric Resistance RH = I²Rt → R = H/(I²t)[ML²T−3A−2]
Self/Mutual Inductance LE = ½LI² → L = 2E/I²[ML²T−2A−2]
Magnetic Field BF = BIl → B = F/(Il)[MT−2A−1]
Magnetic Flux φφ = BA[ML²T−2A−1]
Electric Field EF = qE → E = F/q[MLT−3A−1]
Electric Potential VV = W/q[ML²T−3A−1]
Permittivity ε₀F = q²/(4πε₀r²)[M−1L−3T⁴A²]
Permeability μ₀F = μ₀I₁I₂l/(2πr)[MLT−2A−2]
Coefficient of Viscosity ηF = 6πηrv[ML−1T−1]
Surface Tension SF = Sl → S = F/l[MT−2]
Thermal Conductivity KdQ/dt = KA·dT/dx[MLT−3K−1]
Specific Heat Capacity sQ = msΔT[L²T−2K−1]
Latent Heat LQ = mL[L²T−2]
Magnetic MomentU = MB → M = U/B[L²A] = [M⁰L²T⁰A¹]
Dimensionless Quantities (No Unit or Supplementary Unit)
Charge & Mass Density Formulae
Advertisement
5

Unit–Dimension Relationships — Key Statements

Important True / False — Must Remember
  • A unitless quantity may have dimension → FALSE
  • A dimensionless quantity may be unitless → TRUE (e.g. coefficient of friction)
  • A quantity having unit must have dimension → FALSE (angle has unit = radian but is dimensionless)
  • A quantity having dimension may not have unit → FALSE (dimension implies unit always)

Physical Equation vs Dimensional Equation

Types of Physical Constants
6

Significant Figures

Definition

Number of certain digits + one uncertain digit in a measurement. Indicates the precision of the instrument used.

Rules for Counting Significant Figures
  • Rule 1: All non-zero digits are significant → 44 m = 2 s.f.
  • Rule 2: All zeros between non-zero digits are significant → 405 m = 3 s.f.
  • Rule 3: Zeros on the left side of first non-zero digit are NOT significant → 0.043 = 2 s.f.
  • Rule 4: Trailing zeros after decimal point are significant → 0.06900 = 4 s.f.
  • Rule 5: Trailing zeros without decimal are NOT significant → 2000 g = 1 s.f., 40 cm = 1 s.f.
  • Rule 6: Exact numbers have infinite significant figures → 25 pens = ∞ s.f.
  • Rule 7: Powers of 10 are NOT counted → 2.303 × 10²³ = 4 s.f.
NumberS.F.Reason
44 m2Both non-zero digits count
40 cm1Trailing zero without decimal not significant
405 m3Zero between non-zeros is significant
2000 g1Trailing zeros without decimal not significant
0.043 cm2Leading zeros not significant
30.0435All digits including captured zero
0.069004Trailing zeros after decimal are significant
2.303 × 10²³4Power of 10 not counted

Arithmetic Operations with Significant Figures

⚡ Rounding Off Rules
Q: Number of significant figures in 0.06900?
Leading zeros not significant; trailing zeros after decimal ARE significant → 6, 9, 0, 0 = 4 s.f.
Ans: 4 significant figures ✓
Q: Result of 2.42 + 3.1 + 4.7 to correct significant figures?
Addition → min decimal places = 1 (from 3.1 and 4.7); 2.42 + 3.1 + 4.7 = 10.22 → round to 1 decimal = 10.2
Ans: 10.2 ✓
Advertisement
7

Accuracy and Precision

Definitions
Example — True value = 6.571 m

Measurements: (a) 6.52 m   (b) 6.513 m   (c) 6.61 m   (d) 6.684 m

Most Accurate = (b) 6.513 m — closest to true value 6.571

Most Precise = (b) 6.513 m — maximum decimal places

Note: If true value is not given → most precise = most accurate

8

Error Analysis

Types of Errors
Absolute Error:  δa = |xtrue − xmeasured|
\[ \overline{\delta a} = \frac{\delta a_1 + \delta a_2 + \cdots + \delta a_n}{n} \quad \text{(Mean Absolute Error)} \]
Relative Error = δa̅ / amean
Percentage Error = (δa̅ / amean) × 100%

Combination of Errors — Golden Rule: Errors Always Add

⚡ Special Case — Parallel Resistance Error

If Re = R₁R₂/(R₁+R₂), let Z = R₁ + R₂

\[ \frac{\delta R_e}{R_e} = \frac{\delta R_1}{R_1} + \frac{\delta R_2}{R_2} + \frac{\delta R_1 + \delta R_2}{R_1 + R_2} \]
Q: X = A²B³. Errors in A and B are 2% and 1% respectively. Find % error in X.
δX/X × 100 = 2(δA/A × 100) + 3(δB/B × 100) = 2(2%) + 3(1%) = 4% + 3% = 7%
Ans: 7% ✓
Q: R = V/I, V = (100 ± 5) V, I = (10 ± 0.2) A. Find % error in R.
δR/R × 100 = δV/V × 100 + δI/I × 100 = 5/100 × 100 + 0.2/10 × 100 = 5% + 2% = 7%
Ans: 7% ✓
Advertisement
9

Measuring Instruments

InstrumentLeast Count
Metre Scale1 mm = 0.1 cm
Vernier Calliper0.1 mm = 0.01 cm
Screw Gauge0.01 mm = 0.001 cm
Stop Watch0.1 s or 0.01 s
A

Vernier Calliper

Vernier Scale Principle
\[ \text{Least Count} = 1\,\text{MSD} - 1\,\text{VSD} = \frac{1}{n}\,\text{MSD} \]
Total Reading = MSR + (VSR × LC)
MSR = Main Scale Reading | VSR = number of coinciding Vernier division
⚡ Standard Example

If 10 VSD = 9 MSD (where 1 MSD = 1 mm):

LC = 1 MSD − 1 VSD = 1 − 9/10 = 0.1 mm = 0.01 cm

If MSR = 2.3 cm and 7th division coincides: Total = 2.3 + 7 × 0.01 = 2.37 cm

B

Screw Gauge

Screw Gauge Principle
Pitch = Distance moved on main scale / Number of rotations
Least Count = Pitch / Total divisions on circular scale
Total Reading = Linear scale reading + (Circular scale reading × LC)
Standard: Pitch = 1 mm, Circular divisions = 100 → LC = 0.01 mm
Zero Error in Instruments
Q: In a Vernier calliper, 20 VSD = 19 MSD (1 MSD = 1 mm). Find the least count.
1 VSD = 19/20 MSD; LC = 1 − 19/20 = 1/20 mm = 0.05 mm = 0.005 cm
Ans: LC = 0.05 mm ✓
Q: Screw gauge has pitch 0.5 mm and 50 divisions on circular scale. Linear = 2 mm, circular = 30. Find diameter.
LC = 0.5/50 = 0.01 mm; Total = 2 + 30 × 0.01 = 2 + 0.30 = 2.30 mm
Ans: Diameter = 2.30 mm ✓
Q: Vernier calliper has zero error = +0.02 cm. Observed reading = 3.14 cm. Find correct reading.
Corrected = Observed − Zero error = 3.14 − 0.02 = 3.12 cm
Ans: 3.12 cm ✓
Q: T = 2π√(l/g). Errors in l and g are 1% and 2% respectively. Find % error in T.
δT/T × 100 = ½(δl/l × 100) + ½(δg/g × 100) = ½(1) + ½(2) = 0.5 + 1.0 = 1.5%
Ans: 1.5% ✓
Q: Which is more precise — instrument with LC 0.001 cm or 0.01 cm?
Smaller least count = higher precision
Ans: Instrument with LC = 0.001 cm is more precise ✓